You need to put an end to the silent treatment the cache is currently giving you, and Erlang/OTP has pretty good facilities for doing so. These facilities are the logging application, the SASL application, and the event handling infrastructure that the gen_event behaviour provides. Together, they give you a powerful tool for communicating various types of information to the world at large. The gen_event system even gives you a way to allow other applications to hook into your system.
The logging facility is based on Erlang’s event handling framework, which uses the gen_event behaviour. This behaviour wraps up pretty much everything you need from an event handler in a nice, easy-to-use interface. To plug into the logging infrastructure, you need to write a new gen_event behaviour implementation module. Fortunately, that’s simple. The gen_event behaviour interface is similar to that of the gen_server behaviour: it has the familiar init, code_change, and terminate callback functions, and it also requires the handle_call and handle_info callbacks. (There are some subtle differences when it comes to arguments and return values, so don’t assume too much without checking the documentation.) But the gen_event interface replaces handle_cast/2 with handle_event/2; and as you may be able to guess, that’s where you receive your error-logger events.