Redundancy

As explained in Fundamentals of Cybersecurity

Physical redundancy is the provision of alternate facilities or locations so operations can continue when a primary data center becomes unusable.

Redundancy means providing a backup for something a system needs. If one component fails, another can take over. In a data center, this helps keep services available when equipment breaks or maintenance is needed. section 13.2.1

Backups can be layered rather than relying on one spare component:

  • Power: independent feeds, dual power supplies, uninterruptible power supplies (UPS), and generators provide alternatives during an outage. section 13.2.1 section 13.9
  • Connectivity and computing: redundant Internet access and extra servers provide ways to keep services running. section 13.2.1
  • Location: a geographically separate data center or a pre-configured alternate site provides somewhere to shift operations if the primary site cannot be used. section 13.2.1 section 7.1

How much redundancy is enough depends on how much downtime an organization can tolerate. Higher availability targets require more complex, costly arrangements. A disaster recovery plan should also specify how to activate redundant systems or shift operations; having backups alone does not make recovery automatic. section 13.2.1 section 7.1

Availability
Nickname
Maximum downtime per year
99%
“Two nines”
About 3.5 days
99.9%
“Three nines”
About 9 hours
99.99%
“Four nines”
About 52 minutes
99.999%
“Five nines”
About 5 minutes

Compare availability targets with their maximum yearly downtime before deciding whether additional redundancy is worth its cost. section 13.2.1

When backups are not enough

A 2016 power-surge outage at Delta grounded more than 2,000 flights. Its recovery plan included failover to backup servers, but recovery took nearly six hours. The incident exposed gaps in redundancy and shows why recovery procedures need regular testing. section 7.4

How Fundamentals of Cybersecurity covers it

How deep it goes
Defines duplicate components and compares availability targets and layered backups, but does not provide a procedure for engineering a redundant site.
Examples
Uses redundant power feeds, UPS batteries, generators, servers, and a flight-disrupting outage to show what backups protect and where recovery can falter.
What it assumes
Defines redundancy directly and explains it through familiar failures and backups without requiring prior data-center knowledge.
What you can do after
Evaluate/understand how backup components and alternate sites reduce downtime, and weigh added availability against complexity and cost.
How it connects
Connects redundancy to high availability, failover, uninterruptible power supplies, and disaster recovery planning.

Also explained in

Compare how 13 books explain redundancy →

Related concepts

This explainer was generated by Manning's knowledge graph from the text of Fundamentals of Cybersecurity. The section links point to the parts of the book it draws on.